On the Thermal Performance of the Vapor Chamber with Micro-channel for Unmixed Air Flow Cooling
DOI:
https://doi.org/10.4186/ej.2015.19.1.125Keywords:
Thermal performance, vapor chamber, micro-channels.Abstract
Numerical and experimental results on the thermal performance of vapor chamber with and without micro-channel under constant heat flux are presented. The mathematical model of the vapor chamber is a two-phase closed chamber with wick sheet and a wick column. A finite volume method with structured uniform grid method system is applied to solve the model. Effects of micro-channel on the temperature distribution of the vapor chamber are considered. The results obtained from the model are verified with those from the measured data. The experimental tests are carried out and good agreement is obtained with the numerical results. These numerical results are useful for the design to improvement thermal performance of the vapor chamber and also diminished the expense and time of the real test.
Downloads
Downloads
Authors who publish with Engineering Journal agree to transfer all copyright rights in and to the above work to the Engineering Journal (EJ)'s Editorial Board so that EJ's Editorial Board shall have the right to publish the work for nonprofit use in any media or form. In return, authors retain: (1) all proprietary rights other than copyright; (2) re-use of all or part of the above paper in their other work; (3) right to reproduce or authorize others to reproduce the above paper for authors' personal use or for company use if the source and EJ's copyright notice is indicated, and if the reproduction is not made for the purpose of sale.